Tag Archive for: elevator inspection

full load test

Elevator 5 Year Full Load Test

 

An elevator is a vehicle and requires maintenance just like a car, train or a plane. The required testing is for the safety of the users. Having a 5 year full load test on time saves a home owner lots of headaches and money in the long run. Not only is it required by the state of Connecticut, it is also a requirement of the American Society of Mechanical Engineers.

Per ASME 17.1, requires testing be done every five years. Not having this test could result in your elevator being red-tagged or dubbed as unsafe and therefore disabled.

Procedure:

125% of rated load is placed inside the elevator cab and the elevator is run several times. The mechanic would then reset the governor switch and operate the car at a normal speed in each direction to ensure the ropes stay in place and make sure it stops with distance applicable to the code. This also ensures that the break system is working properly.

The 5 year full load test is not the same as a pressure test. Pressure tests should be done annually.

To schedule elevator testing please call 203-757-5000.